1   1.  Introduction   1.1  The  Definition  of  Environmental  Stress  Cracking   Service  life  is  always  one  of  the  important  factors  people  will  consider  when   picking  the  right  material.  People  used  to  use  a  lot  of  metals,  and  nowadays   plastics  are  developed  so  much  that  they  have  replaced  metals  to  a  large  extend.   So  the  failure  problems  of  plastics  get  more  concerns  than  ever.  Among  all  the   failures  happened  on  plastics,  15%-­‐20%  are  caused  by  environmental  stress   cracking  [1].  It  is  very  interesting  to  both  chemists  and  physicists  as  it  involves,   stress  enhanced  absorption,  permeation,  thermodynamics  of  mixtures,  local   yielding,  cavitations,  fibrillation  and  fracture.  [2]   Environmental  Stress  Cracking  (ESC)  in  plastics  is  the  failure  of  plastics  due  to  the   action  of  both  stress  and  surface-­‐active  substances  (known  as  stress  cracking   agents).  Stress  can  be  external  or  internal  stress  and  these  surface-­‐active  agents  can   be  alcohols,  soaps,  dyes,  agents  containing  moisture.  [1,2,5]  The  source  of  the  stress  is   often  unavoidably  processed  in  during  moulding.  So  even  there’s  no  applied   external  stress,  ESC  is  still  possible.  The  source  of  fluid  contact  is  sometimes   primary,  but  the  existing  of  adhesives,  paints,  lubricants  and  cleaning  agents  are   the  most  often  reasons[1,3,4].   ESC  is  not  a  chemical  reaction  between  the  polymer  and  the  active  environment   even  though  it  results  from  the  interaction  of  the  polymer  with  certain   chemicals.  The  stress-­‐cracking  agents  accelerate  the  process  of  macroscopic   brittle-­‐crack  formation  but  not  in  a  way  of  chemical  degradation  of  polymer  [5].     1.2  The  Cause  of  ESC   When  polymer  subjects  to  a  high  tensile  force  in  the  temperature  above  glass   transition  temperature  (Tg),  the  material  will  reach  a  yielding  point  before   ductile  fracture  happens.  The  time  to  fracture  decreases  with  the  increasing  of     2   tensile  force.    How  about  the  tensile  force  is  low  enough  that  no  locally  yielded   sites  generate?  What  will  be  the  change  in  the  material?       Fig  1.1  Time  dependent  creep  ruptures  strength  of  an  amorphous  plastic   showing  ductile  to  brittle  transition     From  the  figure  above,  we  can  see,  when  the  material  exposes  to  a  low  force  for  a   sufficiently  long  time,  the  material  will  have  brittle  fracture  in  the  last.  Many   factors  can  accelerate  this  procedure,  for  example  higher  temperature,  dynamic   fatigue  and  contact  with  specific  fluids  (ESC)[6].   The  fracture  mechanism  under  high  stress  and  low  stress  is  different:   When  material  is  subject  to  high  stress,  a  high  density  of  locally  yielded  sites  will   be  generated  and  grow,  when  the  yielded  sites  are  big  enough  to  merge  with   each  other,  the  sites  become  a  big  one  and  eventual  macroscopic  yield  failure   happens.  However,  when  material  is  subject  to  low  stress,  only  a  few  sites  will  be   micro-­‐yielded  and  grow  slowly.  The  chance  to  meet  the  neighbors  and  coalesce  is   very  little.  But  these  yielded  zones  cavitate  and  fibrillate  to  become  crazes,  which   eventually  reach  a  critical  length  for  fast  crack.  The  absorption  of  fluid  plasticizes   polymer  and  reduces  yield  strength  [2].       3   Another  explanation  about  these  two  fracture  mechanisms  is  “tie  molecules”.  In   amorphous  polymers,  crack  formation  due  to  ESC  begins  with  craze  formation.   Highly  drawn  fibrils  hold  together  these  craze  regions  and  bridge  the  micro-­‐ cracks  and  prevent  their  propagation  and  coalescence;  For  semi-­‐crystalline   polymers,  tie  molecules  connect  the  crystalline  laminas  through  the  amorphous   phase  [5].  The  tie  molecules  play  an  important  role  in  the  mechanical  properties   of  the  polymer,  since  it  is  the  bridge  for  transmission  of  load.  Stress  cracking   agents  lower  the  cohesive  forces  that  maintain  the  tie  molecules  between  the   crystalline  laminas.  Thus  cracking  is  initiated  at  stress  values  lower  than  the   critical  stress  level  of  the  material  [5].   The  fracture  mechanism  for  a  polymer  with  lamellae  crystalline  structure,  e.g.   Polyethylene,  is  shown  in  figure  1.2  –  1.4.     Fig  1.2  Initial  steps  in  the  deformation  of  polyethylene  [7]     Fig  1.3  Steps  in  the  ductile  deformation  of  polyethylene  [7]     4   There  are  three  different  kinds  of  intercrystalline  materials  in  a  semi  crystalline   polymer:  cilia  are  chains  suspended  from  the  end  of  a  crystalline  chain  while   loose  loops  are  chains  begin  and  end  in  the  same  lamellae;  the  third  kind  is  tie   molecules,  which  are  chains  begin  and  end  in  adjacent  lamellae.     When  a  large  tensile  load  is  applied  as  shown  in  the  arrow  direction  in  Fig1.2  (b),   some  tie  molecules  cannot  be  pulled  out  any  more  (Fig1.2(c))  and  lamellas  break   up  into  small  units  as  shown  in  Fig1.3(b).  For  a  small  tensile  load,  the  large-­‐scale   fiber  pullout  is  not  attained,  the  loading  situation  will  stay  like  Fig1.2(b)  for  a   long  time,  but  after  a  critical  time,  most  of  tie  molecules  disentangle  from  the   matrix  and  load  cannot  be  supported  by  the  remaining  few  tie  molecules,  thus   happens  the  brittle  fracture  in  Fig1.4.     Fig  1.4  Final  step  in  the  brittle  failure  of  polyethylene  [7]   Any  stress  cracking  agent  will  help  the  tie  molecules  to  be  pulled  out  from  the   lamellae  [5].     1.3  The  Prediction  of  ESC   Now  there’s  still  no  exactly  effective  way  to  calculate  or  predict  the  influence  of  a   given  fluid  on  a  certain  polymer.[2]  Some  kinds  of  severe  ESC  fluid  can  be   absorbed  by  polymer  very  quickly,  and  the  fast  decreasing  of  hardness  and   strength  would  cause  a  fast  fracture.  Not  all  the  liquids  have  this  significant   impact  even  though  almost  every  kinds  of  fluid  are  more  affinitive  than  air.     5   As  there  are  tens  of  thousands  of  fluids  in  the  world,  as  well  as  thousands  of   plastics,  how  can  we  know  if  this  plastic  is  safe  to  use  in  contact  with  a  particular   fluid?  But  as  no  system  way  is  found  to  calculate  the  impact,  what  we  can  do  is   prediction  or  testing.   There’re  some  generalizations  made  by  scientists  who  work  on  this  area  for  a   long  time.  Normally  amorphous  thermoplastics  or  thermoplastics  in  their   amorphous  state  are  more  prone  to  ESC  than  the  semi-­‐crystalline  state  or   thermoset.  As  the  structure  of  the  crystalline  is  more  packed,  not  like  the  loose   structure  in  the  amorphous  phase.  So  fluid  cannot  go  into  crystalline  as  easy  as   amorphous  phase.  For  the  thermoset,  as  it’s  cross-­‐linked  between  molecular   chains,  the  diffusion  of  fluid  also  meets  barrier.  Another  rule  is  about  hydrogen   bonding.  More  details  about  hydrogen  bonding  will  be  discussed  later  in  this   chapter.  D.Wright[2]  found  that  fluids  with  modest  hydrogen  bonding  are  most   likely  to  be  severe  or  moderate  stress  cracking  agents.  But  also  in   Bistra’spaper[5],  she  indicated  that  fluids  with  a  low  hydrogen  bonding  are  prone   to  be  severe  or  moderate  ESC  agents.  In  Isaksen’s  early  works[8],  he  carried  out   experiments  on  many  fluids  tried  to  correlate  fluids  parameters  to  ESC,  but   found  no  close  relation  between  hydrogen  bonding  and  ESC.  It’s  possible  this   rule  only  works  in  some  kinds  of  polymers  but  maybe  not  for  all  the  plastics.   Fluids  with  a  high  molar  volume  have  fewer  possibilities  to  be  severe  stress   cracking  agents  [2].  Because  high  molar  volume  leads  to  high  viscosity  and  it’s  not   easy  to  move  freely  with  a  high  viscosity.  Similar  rule  is  plastics  with  high  melt   flow  index  suffer  from  reduced  ESC  resistance[2],  as  it’s  not  easy  for  the   movement  of  fluid  molecules  in  polymer  chains  with  large  molecular  weight.   Amorphous  plastics  are  most  susceptible  to  ESC  at  temperatures  that  approach   their  Tg[2].  This  due  to  the  increased  free  volume  in  polymers  as  Tg  is   approached,  which  facilitates  fluid  permeation  into  the  polymer.   Early  research  indicated  total  solubility  parameter  of  the  fluid  was  the  most   critical  factor.  This  parameter  is  from  the  total  cohesion  energy  of  the  substance.   If  the  polymer  and  fluid  have  similar  total  solubility  parameter,  then  the  polymer   tends  to  absorb  more  fluid  than  the  one  doesn’t  have  a  similar  total  solubility     6   parameter.  This  theory  only  works  well  with  the  solubility  parameter  less  than   10,  it’s  not  able  to  predict  the  performance  between  polymer  and  fluid  which   have  a  total  solubility  parameter  more  than  10[2].   With  more  research  on  solubility  parameter,  scientists  found  the  total  cohesion   energy  of  a  liquid,  E,  can  be  divided  into  at  least  three  separate  parts  either  by   experiment  or  by  calculation[9].  In  the  three-­‐parameter  Hanson  approach,  these   parts  quantitatively  describe  the  non-­‐polar  (atomic),  dispersion  interactions,  ED,   permanent  dipole-­‐permanent  dipole  (molecular)  interactions,  EP,  and  the   hydrogen-­‐bonding  (molecular)  interactions,  EH.   E  =  ED  +  EP  +  EH                                                                                                                                                                                                                                                  (1)   Dividing  this  equation  by  the  molar  volume,  V,  gives  the  respective  Hansen   cohesion  energy  (solubility)  parameters.   E/V  =  ED/V  +  EP/V  +  EH/V                                                                                                                                                                                                      (2)   δ2=  δD2  +δP2  +δH2                                                                                                                                                                                                                                          (3)   The  total  cohesion  energy  divided  by  the  molar  volume  is  the  total  cohesion   energy  density.  The  square  room  of  this  is  the  Hildebrand  total  solubility   parameter,  δ.  The  SI  units  for  these  are  MPa1/2.   Now  there’re  more  models  used  to  predict  this  ESC  phenomenon.  Isaksen[8]  used   polar  parameter  to  predict  ESC  for  HDPE  and  he  established  a  reasonable   correlation  between  equilibrium  absorption  and  time  to  fail  together  with  polar   solubility  parameter.  In  his  study,  polyethylene,  which  has  the  lowest  polarity  of   all  polymers,  is  the  most  rapidly  attacked  by  fluids  of  (similar)  low  polarity.   Hansen  and  Just  [10]  reported  the  results  that  confirm  ESC  phenomena  in  plastics   depend  on  the  size  and  shape  of  the  test  liquid’s  molecules  as  well  as  their   Hansen  Solubility  Parameter  (HSP)  relative  to  those  of  the  polymer.   Peter  J.  Walsh  and  A.J.  Lesser  [11]  probed  a  hypothesis  for  predicting  a  critical   stress  associated  with  of  ESC.  An  experimental  technical  involving  contact  angle   measurements  of  a  sessile  drop  as  function  of  stress  is  used.  But  they  still  need   further  experiments  to  look  at  the  effect  of  contact  angle  on  ESC.     7   1.4  Assessment  by  Testing   There  are  a  variety  of  test  methods  available  for  assessing  the  ESCR  of   thermoplastics.  Mainly  they  are  constant  strain  or  constant  stress  testing.  But   constant  strain  test  is  always  less  severe  than  the  equivalent  test  involving  the   application  of  a  constant  load  because  the  stress  in  the  sample  induced  by   constant  stain  will  decay  with  time  due  to  stress  relaxation.     1.4.1  Constant  Strain  Tests   Constant  strain  tests  are  most  commonly  used  because  they  are  cheap  to  carry   out.  The  problem  for  this  kind  of  tests  is  stress  relaxation  mentioned  in  the   paragraph  above.     1.4.4.1  Bell  Telephone  Test  (BTT)  for  Flexible  Materials   In  the  test,  a  strip  of  the  material  is  bent.  The  maximum  surface  strain  is  given   by:   ε=  t/  (w-­t)                                                                                                                                                                                                                    (4)   Where  w  is  the  width  of  the  holder  and  t  is  the  material  thickness.  This  method  is   quite  crude  and  cheap  and  only  really  used  for  quality  control  testing  of   polyethylene.[2]     1.4.2  Constant  Stress  Tests       8   1.4.2.1  Single  Cantilever  for  Rigid  Materials   It’s  a  simple  method  without  dedicated  investment.  A  strip  of  the  material  is   clamped  to  the  edge  of  a  sturdy  bench.  The  fluid  is  applied  to  the  upper  surface.   As  a  control  it  is  recommended  that  the  same  configuration  be  run  concurrently   in  the  absence  of  the  fluid.  [2]     1.4.2.2  Tensile  Creep  Test   A  high  temperature  tensile  creep  rupture  testing  device  which  is  applicable  to   both  rigid  and  flexible  materials  was  developed  by  Rapra.  [2]  It’s  quite  similar  to   the  common  test  at  constant  load.  It  involves  application  of  a  tensile  stress  and   the  recording  of  the  time  to  rupture.  Even  though  the  name  is  high  temperature   creep  testing  device,  it’s  also  possible  to  work  in  normal  temperature.  This  is  the   device  on  which  the  creep  tests  in  this  paper  carry  out.       1.5  Aim  of  the  Project   The  aim  of  this  project  is  to  investigate  the  properties  of  a  POE  hose,  especially   the  environmental  stress  cracking  resistance  property.  And  if  there’s  any   relatively  simple  way  to  predict  if  the  hose  can  be  used  to  contain  the  given  fluid.     9   2.  Experimental   2.1  Materials   In  this  chapter,  different  tests  are  explained.  All  the  materials  used  in  the   following  tests  were  taken  from  the  POE  hose  (SPX  DN13)  (figure  2.1),  which  is  a   commercial  product  of  LK  Pex.  The  raw  material  used  for  the  hose  was  POE.  It  is   a  kind  of  thermo  elastomer  made  by  in-­‐situ  polymerization  of  ethylene  and   octene  in  metallocene  catalyst.  The  soft  chain  structure  of  octene  and  crystallized   ethylene  chain  make  POE  not  only  stiff  but  also  easy  to  process.  The  saturated   structure  makes  it  excellent  ageing-­‐resistant  material.  Now  it’s  widely  used  in   cable  industry,  automotive  industry  as  well  as  household  appliance  industry.     Fig  2.1  Photo  of  a  specimen  cut  from  the  hose     2.2  Apparatus   2.2.1  Tensile  Test   The  aim  of  the  tensile  test  is  to  get  the  stress  and  strain  for  the  hose  to  break  in  4   kinds  of  liquids.  They  were  xylene,  acetic  acid,  Igepal  CO-­‐630  and  water.   Tensile  test  was  carried  out  in  the  Rheology  Lab,  Department  of  Materials  and   Manufacturing  Technology,  Chalmers  University  of  Technology.  The  model  of  the   tensile  test  machine  was  ZWICK.    LK  Pex  modified  the  grip  of  the  tensile  test   device  in  order  to  fit  the  shape  of  hose.  Figure  2.2  is  a  photo  of  tensile  test  device   (left)  and  a  close  look  of  the  new  grip  (right).  For  the  new  grip,  it’s  clear  to  see   how  it  works  in  figure  2.3.  There  are  two  pieces  of  sample  holders  holding  the     10   ring.  When  the  grips  go  upwards,  the  upper  piece  of  sample  holder  will  also  go   upwards  and  thus  the  elongation  of  the  ring.     Fig  2.2  Photo  of  tensile  test  machine  and  a  close  look  of  new  grip                                       Fig  2.3  Sketch  of  the  grips  before  test  (left),  in  the  test  (right)   Here  is  the  process  for  the  experiment:  a  section  of  hose  (ring)  with  a  length  of   12  mm  (Fig  2.1)  was  cut  from  a  long  hose  and  fixed  in  the  machine  as  shown  in   photo.    The  crosshead  can  travel  with  a  speed  preset  on  the  software.  Then  the   crosshead  would  drive  the  movement  of  grips.  So  the  hose  got  elongation.  Once   the  crosshead  began  to  move,  one  kind  of  liquid  was  applied  on  the  outer  surface   of  the  ring  using  a  burette.  There  was  a  hole  designed  in  the  bottom  base  of  the   device  to  accept  the  liquid  from  the  hose  for  the  sake  of  protecting  the  device.  To     11   assure  that  there’s  always  liquid  on  the  ring,  the  liquid  should  be  applied  on  the   surface  very  often  until  the  break  happened.     The  2000N  load  cell  was  used  in  the  experiment  and  speed  set  for  crosshead  was   20mm/min  for  the  first  minute  and  2mm/min  later  on.   Tensile  tests  were  carried  out  with  the  dry  ring  and  also  on  the  rings  with  four   different  agents.  They  were  xylene,  acetic  acid,  Igepal  CO-­‐630  and  water.  Three   to  four  times  of  repetitions  were  done  for  every  different  liquid.     2.2.2  Creep  Test   The  rig  for  the  creep  test  was  designed  by  LK  Pex.  It’s  a  developed  version  of   tensile  creep  rupture  rig  from  Rapra[2].  The  software  used  here  was  Creep   Software  EC  04  from  the  company  Elastocon  AB.  A  photo  of  the  tensile  creep  test   rig  is  shown  in  figure  2.4.       Fig2.4  Photo  of  creep  test  machine  which  is  developed  from  Rapra  tensile  creep   rupture  rig   When  compare  this  rig  with  the  one  from  Rapra,  there  are  several  advantages  for   the  new  rig  designed  by  the  company.  First  a  digital  device  was  installed  to   measure  and  record  the  elongation  of  specimen.  Secondly,  the  special  curve     12   design  of  the  link  between  the  lever  and  movable  head  for  holding  the  sample   allows  more  accurate  recording  of  the  sample  elongation.  Also  the  design  of  the   solvent  tank  makes  it  easier  to  carry  out  creep  tests  with  several  different   challenging  liquids,  as  it’s  easier  to  change  the  liquid  and  safer  for  the  operator.     The  validation  of  the  new  rig  was  done  by  comparing  the  elongation  figure  in  the   digital  device  with  the  figure  got  from  a  vernier  caliper.  The  result  showed  that   most  of  the  time  the  figures  shown  in  device  were  exactly  the  same  as  what  got   from  vernier  caliper.  Even  there  was  difference  some  times,  the  difference  was   small  enough  to  neglect.   By  doing  the  test,  first  to  do  was  balance  the  lever  with  the  left  side  and  right   side.  The  left  side  had  the  weight  of  the  empty  weight  pan,  weight  of  pointer   from  digital  gauge  and  also  the  self-­‐weight  of  left  side  lever.  The  right  side  had   the  weight  of  one  of  sample  holder,  the  upper  part  of  crosshead,  the  weight  of   right  side  lever  and  the  counter  balance.  The  lever  can  be  equilibrious  by  moving   the  counter  balance.  After  the  lever  was  balanced,  the  similar  specimen  was  cut   as  the  one  in  the  tensile  test,  and  then  dimensions  were  measured.    The   specimen  was  fixed  on  the  sample  holder.  The  sample  holder  was  then  placed  in   the  socket  of  the  crosshead.  Pour  the  liquid  in  the  tank  and  add  the  weights  to   the  weight  pan  as  soon  as  finishing  pouring  the  liquid.  The  time  interval  for  the   two  procedures  should  be  short  because  if  it  delayed,  it’s  possible  some  of  the   liquids  can  be  plasticizer  for  polymer,  the  property  of  polymer  would  change  as   well  as  the  creep  feature.     In  the  creep  tests,  the  same  liquids  as  in  the  tensile  test  were  used.  They  were   xylene,  acetic  acid,  Igepal  CO-­‐630  and  water.   Several  pre-­‐tests  were  done  before  the  formal  tests  to  decide  how  much  weight   should  be  put  on  the  weight  pan.  The  weight  should  not  be  too  large,  otherwise   the  elongation  may  exceed  the  measuring  range  of  the  rig  and  also  a  large  force   may  not  lead  to  environmental  stress  cracking  due  to  the  generation  of  a  high   density  of  local  yielded  sites.  Meanwhile  a  too  small  weight  is  also  not  preferred   as  it  may  take  a  longer  time  for  the  plastic  to  have  feature  changes.       13   After  several  pre-­‐tests,  a  weight  of  2.5  kg  to  3.5  kg  was  chosen.  And  for  the  sake   of  time  limit  of  the  project,  most  of  the  creep  tests  were  stopped  in  5  days  or   when  there  was  an  obvious  change  in  the  strain  rate.   Then  came  the  analysis  of  data  in  the  last.  However,  as  the  POE  hose  specimen   can  elongate  as  much  as  10  times  of  the  original  length  before  breaking,  it’s  out   of  the  rig’s  record  ability.  Also  an  elongation  of  10  times  is  not  interested  for  the   project  as  in  the  real  service  condition  a  hose  will  never  elongate  so  much.  So  in   the  test,  only  a  100%  elongation  was  recorded.  And  then  the  strain  rate  during   elongation  was  analyzed.     Fig  2.5  A  strain  logt  sketch  from  uniaxial  creep  rupture  in  glass   fiber/polyester.[12]   From  figure  2.5  we  can  see,  a  polymer  has  three  different  stages  of  elongation   during  the  creep  test.  The  first  stage  is  the  elastic  elongation  (not  shown  in  the   figure).  The  secondary  creep  is  a  relatively  flat  stage.  After  that  comes  the   tertiary  creep,  which  is  also  the  initiation  of  fracture.[12]  In  the  test,  an  earlier   appearance  of  the  third  stage  is  judged  as  a  quicker  fracture  initiation.       14   2.2.3  Swollen  Test   The  hose  we  used  in  the  experiment  was  cross-­‐linked  by  0.5%  peroxide.  The   degree  of  cross-­‐linking  is  a  very  important  aspect  in  the  characterization  of   polyethylene  based  polymers.   The  way  to  carry  out  swollen  test  was  a  classic  way  first  used  by  P.J.  Phllips  and   W.S.  Lambert  using  boiling  xylene  [13,14].  Figure  2.6  is  the  photo  of  swollen  test   device.   Xylene  was  supplied  by  Fisher  Scientific,  analytical  reagent  grade.     Fig  2.6  Photo  of  the  device  for  swollen  test     Fig  2.7  Photo  of  thin  films  from  POE  hose  for  swollen  test   Thin  films[15]  (figure  2.7)  from  the  POE  hose  of  known  weight  were  immersed  in   boiling  xylene  (138  0C  –  140  0C)  in  a  stainless-­‐steel  basket  for  72  hours  to  allow       15   the  extracting  of  uncross-­‐linked  polymer.  Afterwards  the  basket  with  the   remaining  part  of  the  film  was  transferred  into  a  xylene-­‐containing  flask  and   held  at  1100C  oil-­‐bath  for  24  hours.  This  was  for  the  swelling  of  the  cross-­‐linked   matrix.  The  sample  was  transferred  to  a  clean  dry  tared  weighing  bottle  for   weighing  without  delay.  Here  it  should  be  very  careful  as  the  sample  should  not   be  squeezed  and  the  transfer  of  specimen  should  be  made  quickly.  The  surfaces   should  not  be  subjected  to  excess  blowing.  After  recording  the  weight  in  swollen   state,  the  sample  with  opened  weighing  bottle  was  transferred  to  a  vaccum  oven   (Heraeus  Vacutherm,  Thermo  Scientific)  at  1100C  for  24  hours.  Two  groups  of   POE  hose  made  in  different  times  were  used  in  the  experiments  with  3   repetitions  in  each  group.  Estimates  of  percentage  of  extractables  were  obtained   using  the  weight  loss  of  POE.  The  molecular  weight  between  crosslinks  was   estimated  using  the  Flory-­‐Rehner  equation  as  follows[14,16,17]:     V2  =  (W2/ρ2)/[W2/ρ2+(W1-­‐W0)/ρ1]                                                                                                                      (5)   v  =  -­‐[ln(1-­‐  V2)+  V2  +  χV22]/  V1(V21/3  -­‐  V2/2)                                                                                                                                  (6)   Mc  =ρ2/v                                                                                                                                                                                                                                                                  (7)   Where  v  is  the  effective  network  chain  density,V2  is  the  volume  percentage  of   polymer  in  a  swollen  sample,  V1  is  the  molar  volume  of  solvent,  χ is  the  Flory-­‐ Huggins  polymer/solvent  interaction  parameter,  W0  is  the  weight  of  polymer   before  swelling,  W1  is  the  weight  of  polymer  after  swelling,  W2  is  the  weight  of   polymer  after  vacuum  drying,  ρ1  is  the  density  of  solvent,  and  ρ2  is  the  density  of   polymer.  In  the  calculation  of  MW,  the  values  of  V1  and  χ  are  136  mL/mol  and   0.37,  respectively.[14]   .       16   2.2.4  Density  test   Density  test  was  done  in  SP  (Swedish  National  Testing  and  Research  Institute)   Gothenburg.  Figure  2.8  is  the  photo  of  the  device  for  density  measurement.       Fig  2.8  Density  Gradient  Column  in  SP,  Gothenburg     First  prepare  the  liquid  in  the  column.  Fill  a  certain  amount  of  2-­‐propanol  in  a   flask  with  a  thin  pipe  in  the  bottom  part.  The  thin  pipe  goes  down  until  the   bottom  of  the  column.  Add  water  to  the  flask  with  a  certain  slow  speed.  Because   of  gravity,  the  liquid  in  the  flask  will  go  to  the  column  through  the  thin  pipe.  As   there’s  difference  in  the  density  of  water  and  2-­‐propanol,  there  will  be  a  density   gradient  of  the  liquids  in  the  column.  It  takes  one  day  to  finish  filling  the  column.   Let  the  liquid  stay  still  for  1-­‐2  days  to  assure  no  bubbles  in  the  column.  Now   there’s  a  linear  relationship  between  the  position  of  the  liquid  and  density  in  the   middle  part  of  the  column.  Two  small  floats  with  pre-­‐known  densities  (907.3   kg/m3  and  898.5  kg/m3)  are  put  in  the  liquids.  Then  the  densities  of  the  liquids   in  the  position  of  the  floats  could  be  known.  So  when  a  sample  with  unknown   density  was  put  in  the  column  and  stay  still  between  the  two  floats,  the  density  of   the  sample  can  be  estimated.     17   3.  Results  and  Discussion   3.1  Calculation  of  the  Total  Solubility  Parameter  of  POE   The  cohesive  energy  density  or  solubility  parameter  of  polymers  cannot  be   calculated  via  the  heat  of  vaporization,  because  the  energy  for  separating  the   molecular  chains  is  always  larger  than  breaking  down  the  polymer  into  small   molecules.  An  indirect  method  is  to  find  the  best  solvents  for  the  polymer.  The   solubility  parameters  of  the  polymer  would  then  equal  that  of  the  solvents.   Alternatively  the  molar  attraction  constants  (G)  for  sub-­‐molecular  groups  may   be  used  to  provide  a  calculated  value[18].  Values  for  groups  in  POE  are  given   below:   -­‐CH2-­‐    =  133;    -­‐CH-­‐  =  28;    -­‐CH3  =  214;     For  POE  used  in  the  experiment,  the  percentage  of  ethylene  and  octene  are   treated  as  commercial  secret  by  the  supplier.  The  structure  of  this  polymer  is:     δ=  d•G/M                                                                                                                                                                                                                                                    (8)   Where  M  is  the  molecular  weight  of  a  repeat  unit  (28x+112y)  and  d  is  the  density   (0.909  g/cm3,  density  test  will  be  presented  later  in  this  article).   For  POE  used  in  this  test,     G  =  (133+133)•x+  (133  +28+133•5+214)•y  =  266x+1040y   G/M  =  ()/(28x+112y)  =  9.5  –y/(x+4y)  =  9.5  –1/(x/y+4)   G/Mmin  =  9.5-­‐0.25  =  9.25      (when  x/y→0)     18   G/Mmax  =  9.5-­‐0  =  9.5            (when  x/y  →∞)     δmin =  d•(G/M)min  =  0.909•9.25  =  8.408  (cal/cm3)1/2  =  17.24  MPa1/2   δmax =  d•(G/M)max  =  0.909•9.5  =  8.636  (cal/cm3)1/2  =  17.70  MPa1/2     So  the  total  solubility  parameter  for  POE  is  between  17.24  and  17.70  MPa1/2.   As  polarity  comes  from  the  misalignment  of  positive  electric  charge  center  and   negative  electric  charge  center,  normally  molecules  with  symmetrical  structure   have  a  low  polarity.   The  structure  of  the  main  chain  of  POE  is  very  regular  and  symmetrical.  The  side   group  –(CH2)5CH3  has  a  very  low  polarity,  plus  normally  polymer  has  a  long   chain,  side  group  would  stay  on  the  two  sides  of  main  chain,  which  causes  an   even  lower  polarity.   So,  POE  has  a  very  low  polar  solubility  parameter.     3.2  Tensile  test   Before  showing  the  result  of  tensile  test,  here  is  some  explanation  of  calculation   of  stress  and  strain.         Fig.  3.1  Cross-­‐section  view  of  initial  ring  on  the  sample  holder     19     Fig  3.2  Cross-­‐section  view  of  ring  and  sample  holder  during  a  test     The  length  of  the  dash  line  in  the  schematic  is  the  length  of  ring  used  in   calculation.  As  the  ring  has  an  initial  thickness  of  around  2.2  mm,  during  the  test,   ring  was  becoming  thinner  and  thinner,  the  actual  thickness  at  a  certain  time   cannot  be  known.     After  some  measurements  of  thickness  during  the  test  and  also  for  the  sake  of  an   easy  calculation,  following  assumption  is  made:   When  the  crosshead  travels  between  0-­‐10  mm,  the  length  of  the  ring  which   contacts  the  ring  holder  is  the  initial  ring  length  which  is  46.472  mm.   When  it  goes  between  10-­‐20  mm,  the  length  is  46,  when  it  goes  between  20  -­‐  30   mm,  the  length  is  45;  and  the  like.  At  last  before  the  break,  as  the  ring  is  so  thin   that  the  thickness  can  be  neglected.  The  length  of  ring  which  contacts  the  holder   is  40.3.   σ  =  F/A0                                                                                                                                                                                                                                                          (9)    A0  =  2•t•w                                                                                                                                                                                                                                                (10)   w  is  the  width  of  the  ring;   ε  =  (l-­l0)/l0                                                                                                                                                                                                                                                (11)     l0  is  the  initial  length  of  the  ring;  l  is  the  length  of  ring  at  a  certain  time;   True  stress    σt  =  σ•(1+e);                                                                                                                                                                                              (12)   True  strain    εt  =  ln(1+e)                                                                                                                                                                                                    (13)     20     Table  3.1  shows  the  result  of  the  different  test  groups  in  tensile  test.  The  result   shows  in  Table  3.1  is  the  mean  value  of  4-­‐5  repetitions  in  the  corresponding   group.  As  mean  values,  they  can  better  represent  the  property  of  material  but   stress-­‐strain  plot  of  material  from  beginning  of  the  test  to  the  end  cannot  be   gained  from  the  mean  value.  So  Table  3.2  shows  the  result  of  typical  run  in  each   group,  which  has  the  closest  value  as  the  mean  value.  The  further  analysis  is   based  on  these  typical  tests.       Table  3.1  Result  of  tensile  test   Sample   Stress(MPa)   Strain   True   stress(MPa)   True  strain   Dry  specimen   23.21   5.37   147.87   1.85   Specimen  with   water   23.40   5.26   146.43   1.83   Specimen  with   xylene   18.79   4.95   111.73   1.78   Specimen  with   acetic  acid   20.92   5.08   127.12   1.80   Specimen  with   Igepal  CO-­‐630   23.15   5.30   145.80   1.84                   21     Table  3.2  Result  of  typical  run  in  each  test  group   Sample   Stress(MPa)   Strain   True   stress(MPa)   True  strain   Dry  specimen   22.99   5.44   148.12   1.86   Specimen  with   water   24.17   5.35   153.40   1.84   Specimen  with   xylene   18.14   4.86   106.27   1.77   Specimen  with   acetic  acid   20.47   5.04   123.61   1.80   Specimen  with   Igepal  CO-­‐630   22.90   5.32   144.67   1.84       Fig  3.3  Stress-­‐strain  chart  of  samples  in  different  agents       22     Fig  3.4  True  stress-­‐true  strain  chart  of  samples  in  different  agents     From  these  figures,  we  can  see:   1. No  big  difference  is  shown  between  the  dry  samples  and  samples  in  water  or   Igepal.   2. Acetic   acid   and   xylene   have   quite   big   influence   on   the   ring.   The   stress   to   break  decreases  25%  for  sample  in  xylene  compared  with  dry  sample.  While   for  acetic  acid,   it   is  14%.  The  decreasing  is   large  enough  to  convince  people   the  impact  of  xylene  and  acetic  acid  on  POE  hose.     Igepal  CO-­‐630  is  the  most  commonly  used  stress  cracking  agent  for  evaluating   polyethylene  or  ethylene  copolymer  because  it  has  a  solubility  parameter  of   20MPa  which  is  not  far  from  PE’s  16.4MPa  or  POE’s  17MPa.  But  here  there  was   little  influence  of  Igepal  CO-­‐630  on  tensile  test.  One  of  the  reason  is  Igepal  CO-­‐ 630  has  a  relatively  high  molar  volume  (600cm3/mol),  the  degree  of  absorption   is  low  under  zero  stress,  but  increases  with  increasing  stress.[2]  But  experiments   also  show  that  there  is  little  difference  between  Igepal  and  air  in  the  rupture  test     23   which  is  less  than  15  hours.  This  means  Igepal  is  a  slow  runner.  Tensile  test  was   less  than  20min  for  each  specimen.  This  explains  why  Igepal  has  little  influence   here.     3.3  Creep  test     Fig  3.5  Strain-­‐logt  plot  of  POE  in  acetic  acid  with  a  range  of  loading   There  are  some  small  fluctuation  in  the  beginning  of  the  curves,  it’s  because   weight  pan  was  held  by  hand  when  loading  these  weights  on  the  pan.  Small   movement  of  the  weight  pan  caused  by  hand  was  recorded.   From  figure  3.5  we  can  see  an  earlier  third  stage  comes  with  a  relative  large   loading,  which  means  an  earlier  fracture  will  happen.  What  can  also  be  observed   is  that  the  curve  for  stress  of  0.975  MPa  (with  a  loading  of  3.5kg)  is  different   from  those  with  smaller  loadings.  It  doesn’t  have  a  flat  stage.  Possible  because   this  loading  is  large  enough  that  the  equilibrium  stage  of  the  external  force  and   force  from  tie  molecules  quickly  passed.         24     Fig  3.6  Strain-­‐logt  plot  of  POE  in  different  fluids  with  a  constant  stress  of  0.557   MPa  (with  a  loading  of  2.5kg)     Fig  3.7  Strain-­‐logt  plot  of  Igepal  in  concentration  of  100%  and  40%  with  a   constant  stress  of  0.557  MPa  (with  a  loading  of  2.5kg)   From  the  above  two  figures,  we  can  see:     25   Almost  no  influence  was  brought  by  water  compared  with  sample  in  air.  They   have  same  modulus  as  well  as  the  shape  and  trend  of  the  curves.   Igepal  CO-­‐630  has  a  smaller  modulus  compared  with  dry  sample,  but  in  the   limited  time  recorded  in  the  experiment,  still  there’s  no  big  difference  of  the   shape  of  the  curve.   Acetic  acid  shows  a  third  stage  after  about  15  hours.   Obviously  xylene  is  the  most  severe  ESC  agent  among  all  the  fluids  shown  here.  It   has  a  third  stage  in  less  than  8  hours.  And  from  the  observation  of  sample  after   creep  test,  xylene  was  the  fluid  POE  absorbed  most.   Table  3.3  HSP  of  four  fluids  in  the  test.[9]   Fluids   δD   δP   δH   δT   Xylene   Acetic  acid   Igepal  CO-­‐630   Water     17.8   14.5   /   15.5   0-­‐1   8   Appr.  10   16   3.1   13.5   /   42.4   18   21.3   20   47.9     POE  has  a  total  solubility  parameter  between  17.24  and  17.70,  and  a  polar   solubility  parameter  closes  to  0  and  hydrogen  bonding  closes  to  0.  As  early   work[8]was  done  by  other  scientists  that  they  correlated  polar  solubility   parameter  to  ESC  and  got  a  good  simulation  on  HDPE.  From  the  data  here,  xylene   has  the  closest  polar  solubility  parameter  and  it  is  the  most  severe  ESC  agent,  but   xylene  also  has  the  closest  total  solubility  parameter.  As  lack  of  more  data  to   support,  it  cannot  say  we  have  the  same  conclusion  here.   But  we  can  see  from  this  group  of  data,  that  total  solubility  parameter  has  a  same   sequence  as  the  severity  of  ESC  in  the  range  of  fluids  which  have  similar  molar   volume.  Xylene  has  the  closest  total  solubility  parameter,  follows  acetic  acid  as   well  as  Igepal  CO-­‐630,  and  last  comes  water  which  has  a  largest  difference  in   total  solubility  parameter.   From  figure  3.7  we  can  see  molar  volume  is  very  important  factor.     26   However,  because  of  the  measuring  range  of  the  rig  which  is  less  than  25mm,   while  the  elongation  of  POE  to  break  is  around  220mm,  it’s  not  possible  to   record  ring’s  time  to  rupture.  For  this  reason,  a  figure  like  figure  1.1  cannot  be   obtained  from  the  creep  tests  here.  Also  if  a  ductile  to  brittle  transition  existing   for  POE  cannot  be  judged.  It’s  difficult  to  compare  the  result  with  other   literatures,  e.g.  the  influence  of  crystallinity  or  cross  linking  degree  on  ESC,  as   most  of  the  papers  evaluate  ESC  by  rupture  time  of  material.   The  result  from  creep  test  is  similar  with  the  result  got  from  tensile  test.  Then  it’s   possible  to  have  the  assumption  that  tensile  test  can  predict  ESC  of  chemical   agents  with  a  small  molar  volume.  The  time  for  tensile  test  is  much  less  than  that   of  creep  test.  But  for  these  small  molecules,  they  can  immerse  in  polymer  with   less  hindrance.  Even  the  time  is  short,  they  can  still  impact  the  property  like   chain  entanglement  of  polymer.       3.4  Swollen  test   Table  3.4  Percentage  of  extractables,  molecular  weight  between  crosslinks  and   average  chain  length  between  crosslinks  of  POE  hose   Specimen  nr.   Extractables   (%)   Mw  between   crosslinks   Average  CH2  units   1   2   3   4   5   6   38.3   39.1   37.4   39.2   38.7   38.4   651.9   656.2   649.5   648.5   652.3   649.2   47   47   46   46   47   46     So  the  molecular  weight  between  crosslinks  is  around  650  g/mol,  and  average   CH2  units  between  crosslinks  are  46-­‐47.     27   Compared  with  the  work  done  by  Liao[19],  they  did  swollen  test  on  another  grade   of  POE  and  with  the  same  procedure,  but  the  result  was  very  different  from  the   result  we  get  here.  The  average  molecular  weight  between  crosslinks  is  4108   g/mol  for  0.5  wt%  crosslinking  agent  and  the  extractable  rate  is  20.8%.  And  the   POE  they  used  was  Engage  8003  from  Dow  Chemical  and  the  density  is  0.885   g/cm3  which  has  a  lower  density  than  the  POE  used  here.  It’s  possible  it’s  not  a   linear  polymer  and  has  more  branch  than  the  polymer  we  use.  Branch  could   increase  the  molecular  weight  between  crosslinks  a  lot.  Another  reason  could  be   the  different  use  of  crosslinking  agents.       3.5  Density  Test     Fig  3.8  Result  of  gradient  column  test   Read  from  the  figure  we  can  see  the  density  of  the  POE  hose  is  0.909  g/cm3.The   densities  of  amorphous  phase  and  crystalline  phase  are  0.852  g/cm3  and  1.008   g/cm3,  respectively.     As  degree  of  crystallinity  fc  =  (ρ-­‐  ρa)/(ρc -­‐ρa)                                                                                                          (14)   fc  =  36.5%     28     4.  Conclusion   In  all  the  four  fluids  tested  on  POE,  xylene  has  the  most  severe  ESC  impact  on   POE,  followed  by  acetic  acid  and  Igepal  CO-­‐630,  while  water  almost  has  no   impact  on  POE.  Compare  with  the  ESC  prediction  models  mentioned  in  the   beginning  of  the  article,  total  solubility  parameter  fits  best  with  the  result.  That   is,  for  the  agents  tested  on  POE,    the  more  closer  are  the  total  solubility   parameter  of  the  agent  and  that  of  the  material  (POE),  the  more  severe  effect  on   ESC.  Tensile  test  were  in  some  agreement  with  the  creep  tests.  Within  in  range  of   agents  tested  on  POE,  tensile  tests  were  helpful  towards  investigating  the   severity  of  ESC  but  limited  to  fluids  having  a  small  molar  volume.   29   Recommendations  for  Further  Research   Creep  test  on  more  fluids  can  be  carried  out  in  the  future.  For  example  fluids   with  a  close  total  solubility  parameter  but  different  polar  solubility  parameter  or   close  polar  solubility  parameter  but  different  total  solubility  parameter   compared  with  POE.  Also  POE  with  different  grades  can  be  tested  to  see  how  the   relation  goes  with  density  and  molecular  weight  between  cross  links  with  ESCR.       30   References   1.M.C.  Hough,  D.C.  Wright,  Polymer  Testing  1996,  15,  407-­‐421   2.  D.  Wright,  “Environmental  Stress  Cracking  of  Plastics”,  RAPRA  Technology  Ltd.   Shawbury  1996   3.  J.  Lagaron,  N.M.  Dixon,  B.J.  Kip,  Macromolecules  1998,  31,  5845-­‐5852   4.  J.  Lagaron,  J.  Pastor,  B.  Kip,  Polymer  1999,  40,  1629-­‐1636   5.  B.  Andersen,  Doctoral  dissertation  “Investigations  on  Environmental  Stress   Cracking  Resistance  of  LDPE/EVA  Blends”,  2004   6.  A.  Lustiger,  R.D.  Cornelinssen,  J.  Mater.Sci.  1987,  22,  2470-­‐2476   7.  A.  Lustiger,  “Understanding  Environmental  Stress  Cracking  in  Polyethylene”  in   “Medical  Plastics:  Degradation,  Resistance  &  Failure  Analysis”,  R.C.  Portnoy,   SPE,  Plastic  Design  Library  1998,  p.  66-­‐71   8.  R.A.  Isaksen,  S.  Newman,  R.J.  Clark,  J.Appl.  Polym.  Sci.  1963,  7,  515   9.  C.M.  Hansen,  “Hanson  solubility  parameters-­‐  a  user’s  handbook”,  CRC  Press   LLC,  2000   10.  C.M.  Hansen,  L.  Just,  Ind.  Eng.  Chem.  Res.  2001,  40,  21-­‐25   11.  P.J.  Walsh,  A.J.  Lesser,  J.  Mater  Sci.  2007,  42,  5835-­‐5844   12.  Brostow,  Corneliussen,  “  Failure  of  Plastics”,  Hanser  Publishers  1986   13.  P.J.  Phillips,  Polymer  1990,  31,2077-­‐2082   14.  P.J.  Phillips,  ANTEC  1994,  1476-­‐1479   15.  ASTM  D  2765  –  01  Standard  Test  Methods  for  Determination  of  Gel  Content   and  Swell  Ratio  of  Crosslinked  Ethylene  Plastics,  2006   16.  D.J.  Dijkstra,  W.  Hoogsteen,  A.  Pennings,  Polymer  1989,  30,  866-­‐873   17.  G.  Gielenz,  B.  Jungnickel,  J.  Colloid  Polym.  Sci.  1982,  26,  742-­‐753     31   18.  P.A.  Small,  J.  Appl.  Chem.  1953,  3,  71   19.  H.T.  Liao,  C.S.  Wu,  Polymer-­‐Plastics  Technology  and  Engineering  2003,  42,  1,   1-­‐16