Optimering av processparametrar hos Cap-EDI pilotanläggning för effektiviserad eluering av 7Li från simulerad reaktorkylvattenmatris

dc.contributor.authorAxberg, Anton
dc.contributor.departmentChalmers tekniska högskola / Institutionen för kemi och kemitekniksv
dc.contributor.examinerEkberg, Christian
dc.date.accessioned2020-09-07T12:34:38Z
dc.date.available2020-09-07T12:34:38Z
dc.date.issued2020sv
dc.date.submitted2020
dc.description.abstractCapacitive deionization, Cap-EDI, is an ion separation technology which offers new possibilities in the field of nuclear power. 7Li is an important isotope used in the coolant water in pressurized water reactors, the isotope is however expensive and there is interest in seeing whether or not the isotope can be recycled from the reactor coolant water. Previous tests have shown that Cap-EDI can be used to successfully extract 7Li from reactor coolant water. There are however questions regarding the optimization of the elution of enriched 7Li from the Cap- EDI. This study will evaluate which settings on the process parameters; flow and voltage, gives the best elution of enriched 7Li from the Cap-EDI in order to achieve the highest concentration of 7Li in the eluate. The optimization of the two process parameters was done through the testing of four factorial tests based on a 22 factorial design. Results showed that the highest concentration of 7Li in the eluate was achieved when a high flow and a high voltage was used. Calculations based on the test results pointed to interaction effects between the two parameters, which was expected from the literature study. The final result did however go against expectations in that a low flow with a high voltage was the anticipated combination which would generate the highest concentration of 7Li ions in the eluate.sv
dc.identifier.coursecodeKBTX11sv
dc.identifier.urihttps://hdl.handle.net/20.500.12380/301646
dc.language.isoengsv
dc.setspec.uppsokPhysicsChemistryMaths
dc.subjectCapacitive deionizationsv
dc.subjectCDIsv
dc.subjectMCDIsv
dc.subjectCap-EDIsv
dc.subjectLithium-7sv
dc.subject7Lisv
dc.subjectRecyclingsv
dc.subjectNuclear powersv
dc.subjectPressurized water reactorsv
dc.subjectPWRsv
dc.titleOptimering av processparametrar hos Cap-EDI pilotanläggning för effektiviserad eluering av 7Li från simulerad reaktorkylvattenmatrissv
dc.type.uppsokM2
Ladda ner
Original bundle
Visar 1 - 1 av 1
Hämtar...
Bild (thumbnail)
Namn:
Anton Axberg.pdf
Storlek:
2.48 MB
Format:
Adobe Portable Document Format
Beskrivning:
License bundle
Visar 1 - 1 av 1
Hämtar...
Bild (thumbnail)
Namn:
license.txt
Storlek:
1.14 KB
Format:
Item-specific license agreed upon to submission
Beskrivning: