HVDC Transmission System with Medium-Frequency Transformers

dc.contributor.authorAdil, Mohammed
dc.contributor.departmentChalmers tekniska högskola / Institutionen för energi och miljösv
dc.contributor.departmentChalmers University of Technology / Department of Energy and Environmenten
dc.date.accessioned2019-07-03T12:17:06Z
dc.date.available2019-07-03T12:17:06Z
dc.date.issued2009
dc.description.abstractFor voltage adaptation and galvanic isolation in High Voltage Direct Current (HVDC) converter stations, standard transformers operating at grid frequency are currently used. These devices tend to be very large and heavy, which is undesirable in many applications. Transformers where the magnetic parts operate at a frequency considerably higher than the grid frequency could offer many advantages. Smaller and lighter transformers and lower losses are among them. In this thesis, a future-oriented HVDC converter station using a medium frequency MF transformer is studied with special focus on the converter circuits. The converter size used in this work is 78MW (±75kVDC/11kVAC) and the main application is power transmission to and from offshore installations. The converter consists of a snubbered Voltage-Source Converter VSC and 2-phase by 3-phase cycloconverter connected by a MF transformer. The VSC is implemented using a single phase leg and the cycloconverter is implemented using fast thyristors. It is expected that the semiconductor losses of the power conversion system will be significantly reduced by the use of the proposed converter topology which permits soft switching of all semiconductor valves in all operating points without any auxiliary valve. The thesis evaluates the commercial potential of the proposed HVDC system. A general circuit design based on available preconditions is made first for the studied converter station, and then a comparison with an existing two-level HVDC-Light station with regard to semiconductor requirements and losses is performed for the same operating point. The total space occupied by the valve installations for both systems is also estimated. The comparison shows that the proposed system promises a considerable reduction in the number of semiconductor devices and, as a result, the total volume of the converter valves. However, the semiconductor losses increase slightly.
dc.identifier.urihttps://hdl.handle.net/20.500.12380/105125
dc.language.isoeng
dc.setspec.uppsokLifeEarthScience
dc.subjectElkraftteknik
dc.subjectElectric power engineering
dc.titleHVDC Transmission System with Medium-Frequency Transformers
dc.type.degreeExamensarbete för masterexamensv
dc.type.degreeMaster Thesisen
dc.type.uppsokH
Ladda ner
Original bundle
Visar 1 - 2 av 2
Hämtar...
Bild (thumbnail)
Namn:
AdilMohammedMSc.pdf
Storlek:
476 KB
Format:
Adobe Portable Document Format
Beskrivning:
Fulltext
Hämtar...
Bild (thumbnail)
Namn:
105125.pdf
Storlek:
476 KB
Format:
Adobe Portable Document Format
Beskrivning:
Fulltext