CFD Modeling of an Air-Cooled Data Center

dc.contributor.authorWibron, Emelie
dc.contributor.departmentChalmers tekniska högskola / Institutionen för tillämpad mekaniksv
dc.contributor.departmentChalmers University of Technology / Department of Applied Mechanicsen
dc.date.accessioned2019-07-03T13:45:15Z
dc.date.available2019-07-03T13:45:15Z
dc.date.issued2015
dc.description.abstractFortlax is an air-cooled data center in Norrbotten. The potential of future investments in data centers is prosperous, but sustainability is an increasingly important factor. It is important to make sure that the data centers are sufficiently cooled while too much forced cooling leads to economical losses and a waste of energy. The purpose of this thesis is to develop a CFD model of a server room at Fortlax data center that accurately predicts the temperature and flow field. The goal is to develop the CFD model in order to evaluate different cooling systems and also improve the placement of the server racks. Most of the server racks are only half full at the moment, but the heat load is supposed to increase in the near future. Therefore, it has been assumed that all the server racks generate full heat load. The commercial CFD software ANSYS CFX 16.0 has been used to perform the simulations. The current cooling system with the current placement of the server racks resulted in some insufficiently cooled server racks. The performance of the cooling system was significantly improved when the hard-floor configuration was replaced by a raised-floor configuration. The design strategy based on hot/cold-aisles has become the standard when raised-floor configurations are used. However, the raised-floor configuration with parallel rows of server racks turned out to be the setup that performed best based on the performance metrics that were used to evaluate the results in this thesis.
dc.identifier.urihttps://hdl.handle.net/20.500.12380/219609
dc.language.isoeng
dc.relation.ispartofseriesDiploma work - Department of Applied Mechanics, Chalmers University of Technology, Göteborg, Sweden : 2015:31
dc.setspec.uppsokTechnology
dc.subjectEnergi
dc.subjectHållbar utveckling
dc.subjectStrömningsmekanik
dc.subjectEnergy
dc.subjectSustainable Development
dc.subjectFluid mechanics
dc.titleCFD Modeling of an Air-Cooled Data Center
dc.type.degreeExamensarbete för masterexamensv
dc.type.degreeMaster Thesisen
dc.type.uppsokH
local.programmeApplied physics (MPAPP), MSc