From Spatial to Temporal: A Geometry-Aware Approach to Indoor Thermal Prediction: Cross-building zone-level prediction for rapid summer thermal assessment
Hämtar...
Publicerad
Författare
Typ
Examensarbete för masterexamen
Master's Thesis
Master's Thesis
Modellbyggare
Tidskriftstitel
ISSN
Volymtitel
Utgivare
Sammanfattning
Climate change is increasing warm-season indoor heat exposure and building overheating risk,
especially in Central and Northern Europe, where many homes have limited active cooling. Overheating
varies within a building because floor level, orientation, glazing, shading, envelope properties, and
spatial position affect each thermal zone differently. Many overheating indicators also depend on hourly
operative-temperature trajectories. Therefore, rapid assessment requires both zone-level spatial
resolution and dynamic temporal resolution.
This thesis develops and evaluates a cross-building surrogate framework trained on EnergyPlus
simulations for rapid prediction of zone-level thermal conditions. Parametric buildings provide hourly
operative-temperature reference data. Their geometry, component locations, and thermophysical
properties are converted into sparse three-dimensional representations. The model combines
whole-building and target-zone spatial information with weather, solar conditions, air exchange rate,
and known dynamics of adjacent zones. It predicts hourly operative temperature under a fully separated
building-level training, validation, and test set.
Across 200 independent test buildings evaluated using three fixed 168-hour periods, the proposed model
achieves an operative-temperature MAE of 0.92◦C, an hourly temperature-change MAE of 0.087◦C/h,
and a temperature-change direction accuracy of 94%. Compared with a baseline based on manually
aggregated descriptors, the 3D model provides more consistent performance for overall temperature,
strong temperature transitions, and the complete static-parameter set. Controlled experiments show that
it recovers the main responses to window-to-wall ratio, exterior shading, orientation, and glazing.
Climate-transfer tests retain good performance in Copenhagen and show systematic bias in Munich and
Tromsø, with corresponding changes in high-temperature detection. These results define the current
climate domain of the framework. Reusing the static geometric representation reduces the marginal cost
of repeated evaluation: cached CPU inference are approximately 12.57× faster than repeated
EnergyPlus simulations.
The framework supports rapid zone-level prediction for large-scale urban overheating screening,
building retrofit decision-making, and early-stage building design.
Beskrivning
Ämne/nyckelord
building overheating; indoor thermal environment; operative temperature; zone-level prediction; building-performance simulation; surrogate model; 3D building representation