From Spatial to Temporal: A Geometry-Aware Approach to Indoor Thermal Prediction: Cross-building zone-level prediction for rapid summer thermal assessment

Hämtar...
Bild (thumbnail)

Publicerad

Författare

Typ

Examensarbete för masterexamen
Master's Thesis

Modellbyggare

Tidskriftstitel

ISSN

Volymtitel

Utgivare

Sammanfattning

Climate change is increasing warm-season indoor heat exposure and building overheating risk, especially in Central and Northern Europe, where many homes have limited active cooling. Overheating varies within a building because floor level, orientation, glazing, shading, envelope properties, and spatial position affect each thermal zone differently. Many overheating indicators also depend on hourly operative-temperature trajectories. Therefore, rapid assessment requires both zone-level spatial resolution and dynamic temporal resolution. This thesis develops and evaluates a cross-building surrogate framework trained on EnergyPlus simulations for rapid prediction of zone-level thermal conditions. Parametric buildings provide hourly operative-temperature reference data. Their geometry, component locations, and thermophysical properties are converted into sparse three-dimensional representations. The model combines whole-building and target-zone spatial information with weather, solar conditions, air exchange rate, and known dynamics of adjacent zones. It predicts hourly operative temperature under a fully separated building-level training, validation, and test set. Across 200 independent test buildings evaluated using three fixed 168-hour periods, the proposed model achieves an operative-temperature MAE of 0.92◦C, an hourly temperature-change MAE of 0.087◦C/h, and a temperature-change direction accuracy of 94%. Compared with a baseline based on manually aggregated descriptors, the 3D model provides more consistent performance for overall temperature, strong temperature transitions, and the complete static-parameter set. Controlled experiments show that it recovers the main responses to window-to-wall ratio, exterior shading, orientation, and glazing. Climate-transfer tests retain good performance in Copenhagen and show systematic bias in Munich and Tromsø, with corresponding changes in high-temperature detection. These results define the current climate domain of the framework. Reusing the static geometric representation reduces the marginal cost of repeated evaluation: cached CPU inference are approximately 12.57× faster than repeated EnergyPlus simulations. The framework supports rapid zone-level prediction for large-scale urban overheating screening, building retrofit decision-making, and early-stage building design.

Beskrivning

Ämne/nyckelord

building overheating; indoor thermal environment; operative temperature; zone-level prediction; building-performance simulation; surrogate model; 3D building representation

Citation

Arkitekt (konstruktör)

Geografisk plats

Byggnad (typ)

Byggår

Modelltyp

Skala

Teknik / material

Index

Endorsement

Review

Supplemented By

Referenced By