Finite Element Modelling of Knee Joint and Femur for Future Injury Assessment

dc.contributor.authorSvensson, Gustav
dc.contributor.departmentChalmers tekniska högskola / Institutionen för mekanik och maritima vetenskapersv
dc.contributor.departmentChalmers University of Technology / Department of Mechanics and Maritime Sciencesen
dc.contributor.examinerIraeus, Johan
dc.contributor.supervisorPipkorn, Bengt
dc.contributor.supervisorIraeus, Johan
dc.date.accessioned2022-11-19T13:14:32Z
dc.date.available2022-11-19T13:14:32Z
dc.date.issued2022
dc.date.submitted2020
dc.description.abstractThe purpose of this thesis was to develop and validate a FE model of the femur and knee with associated ligaments, tendons and cartilage. In the future, the model will be integrated into the SAFER HBM representing a 50th percentile male and used to develop the capability of the SAFER HBM to assess femur and knee injury risk. In total, eleven parts, including the femur, patella, anterior cruciate ligament, poste rior cruciate ligament, medial collateral ligament, lateral collateral ligament, patellar tendon, quadriceps tendon and cartilage on the distal end of the femur, posterior side of the patella and on the tibial plateau, were modelled using eight node solid el ements. The femur and the patella models are based on geometry models from a CT scan of a 50th percentile female, and the soft tissue models are based on geometry descriptions found in the literature. The cortical and trabecular bone tissues of the femur and the patella were modelled with isotropic material properties. All models were meshed in accordance to the requirements and quality criteria of SAFER HBM standards. The femur was validated against previously published three-point-bending and com bined loading tests. 23 tests were replicated using explicit LS-DYNA simulations. Two methods were used to evaluate the correlation between the tests and the simula tions. The response of the simulations, reaction force of the actuator versus actuator displacement, were plotted together with statistically evaluated corridors, ±2 stan dard deviations of the mean reaction, from the tests. To assess the correlation in an objective sense, a CORA evaluation was made on the time-history results. The results showed that the average time-force CORA score were 0.720 and 0.752 for the three-point-bending set and the combined load set. This CORA score corresponds to good biofidelity.
dc.identifier.coursecodeMMSX30
dc.identifier.urihttps://odr.chalmers.se/handle/20.500.12380/305815
dc.language.isoeng
dc.relation.ispartofseries2022:73
dc.setspec.uppsokTechnology
dc.subjectFinite Element Modelling
dc.subjectValidation
dc.subjectKnee
dc.subjectFemur
dc.subjectHuman Body Model
dc.subjectSAFER
dc.titleFinite Element Modelling of Knee Joint and Femur for Future Injury Assessment
dc.type.degreeExamensarbete för masterexamensv
dc.type.degreeMaster's Thesisen
dc.type.uppsokH
local.programmeApplied mechanics (MPAME), MSc
Ladda ner
Original bundle
Visar 1 - 1 av 1
Hämtar...
Bild (thumbnail)
Namn:
2022-73 Gustav Svensson.pdf
Storlek:
5.2 MB
Format:
Adobe Portable Document Format
Beskrivning:
License bundle
Visar 1 - 1 av 1
Hämtar...
Bild (thumbnail)
Namn:
license.txt
Storlek:
1.64 KB
Format:
Item-specific license agreed upon to submission
Beskrivning: