Inbyggt styrsystem för elektrisk genomströmningsvärmare - Built-in control system for electric flow heater

dc.contributor.authorMillberg, Tony
dc.contributor.authorBoman, Mikael
dc.contributor.departmentChalmers tekniska högskola / Institutionen för elektrotekniksv
dc.contributor.departmentChalmers University of Technology / Department of Electrical Engineeringen
dc.contributor.examinerOlesen, Veronica
dc.contributor.supervisorJeklind Dybeck, Simon
dc.contributor.supervisorFagerström, Johannes
dc.date.accessioned2026-06-16T15:04:38Z
dc.date.issued2026
dc.date.submitted
dc.description.abstractVyse tech AB utvecklar en produkt som ska minska vatten- och energiförbrukningen hos kranar. Istället för en centraliserad värmepanna värmer produkten vattnet precis innan det når kranen. I denna rapport redovisas utvecklingsprocessen för styrsystemet till en vattenvärmare samt de resultat som framkommit under examensarbetet. Det har funnits två mål med examensarbetet. Det första har varit att utveckla och implementera regleringen av temperaturen i värmeelementet som ska finnas i produkten. Det andra har varit att undersöka och eventuellt eliminera en temperaturdipp som kan ske i början av vissa spolningar av kranen. För att uppnå dessa mål har en iterativ process utförts där tester och resultat kontinuerligt utvecklats. Resultatet av examensarbetet är att den framtagna regulatorn snabbt värmer upp vattnet och har eliminerat översväng i det mest förekommande driftsceneriet. Temperaturdippen är antingen kraftigt reducerad eller helt eliminerad beroende på hur produkten är installerad. Vyse tech AB is developing a product that will reduce water and energy consumption in faucets. Instead of a centralized boiler, the product heats the water just before it reaches the faucet. This report describes the development process for the control system for a water heater and the results that emerged during the degree project. There have been two goals with the degree project. The first has been to develop and implement the control system of the temperature in the heating element that will be in the product. The second has been to investigate and possibly eliminate a temperature dip that may occur at the start of certain flushes of the faucet. To achieve these goals, an iterative process has been carried out where tests and results have been continuously developed. The result of the degree project is that the developed control system quickly heats the water and has eliminated overshoot in the most common operating scenario. The temperature dip is either greatly reduced or completely eliminated depending on how the product is installed.
dc.identifier.coursecodeEENX20
dc.identifier.urihttps://hdl.handle.net/20.500.12380/311328
dc.language.isoswe
dc.setspec.uppsokTechnology
dc.subjectReglerteknik, styrsystem, vattenuppvärmning, energieffektivitet, värmeelement
dc.titleInbyggt styrsystem för elektrisk genomströmningsvärmare - Built-in control system for electric flow heater
dc.type.degreeExamensarbete på grundnivåsv
dc.type.uppsokM
local.programmeElektroteknik 180 hp (högskoleingenjör)

Ladda ner

Original bundle

Visar 1 - 1 av 1
Hämtar...
Bild (thumbnail)
Namn:
Slutrapport_ M Boman_ T Millberg-1.pdf
Size:
5.83 MB
Format:
Adobe Portable Document Format

License bundle

Visar 1 - 1 av 1
Hämtar...
Bild (thumbnail)
Namn:
license.txt
Size:
2.35 KB
Format:
Item-specific license agreed upon to submission
Description: