CFD evaluation of a turbine rear structure with an integrated heat exchanger

dc.contributor.authorSkoglund, August
dc.contributor.authorChalhoub, Elias
dc.contributor.departmentChalmers tekniska högskola / Institutionen för mekanik och maritima vetenskapersv
dc.contributor.departmentChalmers University of Technology / Department of Mechanics and Maritime Sciencesen
dc.contributor.examinerChernoray, Valery
dc.contributor.supervisorAndersson, Sonny
dc.date.accessioned2023-07-07T13:25:40Z
dc.date.available2023-07-07T13:25:40Z
dc.date.issued2023
dc.date.submitted2023
dc.description.abstractThe expanding aviation industry is currently experiencing a substantial transition in order to become more sustainable. A more environmentally friendly alternative to traditional jet fuel is liquid hydrogen, an option that has been investigated by GKN Aerospace among others. Employing liquid hydrogen imposes many engineer ing challenges, one of which is the design on the turbine rear structure part (TRS) of the engine. This section of an aeroplane engine is of special interest to GKN as it is one of their main products. As liquid hydrogen has to be kept at low temperatures in order to remain in its liquid state, a state most suited for use in aircraft due to the low energy density of gases, and as the air exiting an engine is typically very hot this opens the possibility, if not necessity of heat exchange between the fluids. A model of a heat exchanger that can be used for this purpose was constructed by GKN and tested at Chalmers university of technology where the hydrogen was replaced by heated water. A patent for the heat exchanger model had been filed but not obtained during the thesis work which meant that the exact geometry of it was omitted from the thesis. In this thesis the tests at Chalmers were used in order to perform CFD simulations of the turbine rear structure with an integrated heat exchanger. The results obtained from the CFD were then validated by comparing turbulence models and boundary condition specification methods after which the results were compared to the test data. The validity of the used CFD model was confirmed using tests and reasoning although the CFD model was shown to over predict the magnitude of separation zones. The measured outlet temperature of the water was shown to be accurately predicted by the CFD simulations. Additional simulations of a TRS without the heat exchanger were also carried out to highlight the difference between using and not using a heat exchanger. Finally the performance of the heat exchanger was assessed by calculating its effectiveness for the different simulations which gave indications for the optimal air flow through it.
dc.identifier.coursecodeMMSX30
dc.identifier.urihttp://hdl.handle.net/20.500.12380/306624
dc.language.isoeng
dc.setspec.uppsokTechnology
dc.subjectHeat Exchanger
dc.subjectCFD
dc.subjectTRS
dc.subjectLiquid Hydrogen
dc.subjectAeroplane Engine
dc.subjectGKN Aerospace
dc.subjectOGV
dc.subjecthigh BPR turbofan
dc.subjectTurbulence modelling
dc.titleCFD evaluation of a turbine rear structure with an integrated heat exchanger
dc.type.degreeExamensarbete för masterexamensv
dc.type.degreeMaster's Thesisen
dc.type.uppsokH
local.programmeEngineering mathematics and computational science (MPENM), MSc

Ladda ner

Original bundle

Visar 1 - 1 av 1
Hämtar...
Bild (thumbnail)
Namn:
Exjobb_Chalhoub_Skoglund.pdf
Storlek:
24.59 MB
Format:
Adobe Portable Document Format

License bundle

Visar 1 - 1 av 1
Hämtar...
Bild (thumbnail)
Namn:
license.txt
Storlek:
2.35 KB
Format:
Item-specific license agreed upon to submission
Beskrivning: