Average reinforcement strain in reinforced concrete structures loaded until failure - An experimental study on the effect of reduced interaction and reinforcement ratio on plastic deformation capacity

dc.contributor.authorNozad, Arghavan
dc.contributor.authorMoa, Steiner
dc.contributor.departmentChalmers tekniska högskola / Institutionen för arkitektur och samhällsbyggnadsteknik (ACE)sv
dc.contributor.examinerLeppänen, Joosef
dc.contributor.supervisorJohansson, Morgan
dc.date.accessioned2021-06-29T11:52:38Z
dc.date.available2021-06-29T11:52:38Z
dc.date.issued2021sv
dc.date.submitted2020
dc.description.abstractReinforced concrete and its behavior have a significant role in structural engineering. Reinforced concrete structures are usually designed based on Eurocode for static loading which is not sufficient in case of dynamic loading situations such as explosion. For a structure subjected to impulse loading, plastic deformation capacity is of higher importance rather than the load capacity. The regulations provided by the Swedish Fortification Agency, FKR 2011, provides certain design regulation to fulfill requirements for structures subjected to impulse load. According to these regulations for which a revision is needed, average tensile strain of reinforcement at failure is an effective factor representing plastic deformation capacity. The aim of this project was to study the effect of reinforcement amount and decreased interaction between steel and concrete on reinforcement average strain and plastic deformation capacity of reinforced concrete beams subjected to static loading. Therefore, nine beams in three different categories were constructed and subjected to a four-point bending test as: three beams with 10 reinforcement, three beams with 12 reinforcement, and three beams with 12 reinforcement with PVC tubes placed in the middle of the reinforcement to decrease the bond. The number of bars and the dimensions were the same for all beams. Before casting, the reinforcement were marked every 50 mm and then remove after testing to measure the elongation of the bars. Also some bars were 3D scanned as another method to measure the elongation and to analyse the cross-sectional changes. During the tests, the structural response of beams was recorded using Digital Image Correlation (DIC). Although there were some scatter in test results, in general it can be concluded that beams with 12 reinforcement provided a larger plastic deformation capacity compared to beams with 10 reinforcement. Also, application of PVC tubes to reduce the bond between the concrete and the steel resulted in a larger plastic deformation capacity and average reinforcement strain. The utilization rate for strain values was estimated and the reinforcement bars with PVC tubes showed a increase utilization rate.sv
dc.identifier.coursecodeACEX30sv
dc.identifier.urihttps://hdl.handle.net/20.500.12380/302808
dc.language.isoengsv
dc.setspec.uppsokTechnology
dc.subjectReinforced concrete, plastic deformation capacity, average tensile strainsv
dc.subjectbond interaction, DIC, four-point bending test, FKRsv
dc.titleAverage reinforcement strain in reinforced concrete structures loaded until failure - An experimental study on the effect of reduced interaction and reinforcement ratio on plastic deformation capacitysv
dc.type.degreeExamensarbete för masterexamensv
dc.type.uppsokH
local.programmeStructural engineering and building technology (MPSEB), MSc
Ladda ner
Original bundle
Visar 1 - 1 av 1
Hämtar...
Bild (thumbnail)
Namn:
ACEX30 Steiner Moa Nozad Arghavan.pdf
Storlek:
47.16 MB
Format:
Adobe Portable Document Format
Beskrivning:
License bundle
Visar 1 - 1 av 1
Hämtar...
Bild (thumbnail)
Namn:
license.txt
Storlek:
1.51 KB
Format:
Item-specific license agreed upon to submission
Beskrivning: